AS 5113 - For External Wall Fire Spread
作者:admin    发布于:2024-04-02 09:17:40    文字:【】【】【

External wall testing occurs in accordance with AS 5113, with testing completed to BS 8414. The test rig simulates the external wall of a building with a return wall. The test rig is over 9m tall with the main wall 3m wide and the return wall 2m deep. Test samples can be applied to two layers of 13mm fire grade plasterboard or as a full wall system.

The BCA references testing to AS 5113 through the verification Method CV3, where a performance analysis is required for verification of the products use. It is important to note that the wall is a system made of multiple elements where each one has a unique characteristic which may influence the results.

The external wall elements do not need to be conditioned but do need to be kept in a clean and dry state prior to testing. There are set parameters for when the test can be undertaken which excludes when its raining, windy or during high or low temperatures.

Labs has developed a library of solutions for various materials to be incorporated into suitable wall designs that are practical and cost efficient. Ignis Labs is also working on a solution for retrofit installations where we work with building owners to understand their current building compliance and risk options to improve the safety of the building.

AS 5113 60%.jpg


Contact Us:

Tel: (+86) 25 86583475               (+86) 25 86583465
Web:  www.fire-test.com              www.firete.com
Email: info@fire-test.com              fanghuo@vip.163.com
WeChat:firetesting  或 17714189018
...



版权所有 Copyright(C)2012-2015    南京睿督科技有限公司
地址:江苏省南京市建邺区江东中路118号德盈大厦1622 苏公网安备 32010502010098号  
电话:025-8658 3475   传真:025-8658 3457  网址:http://www.nff16-101.com/   邮箱:info@fire-test.com   备案号:苏ICP备10201999号